Effects of Using Benzalkonium Chloride (BZK) Disinfectant Against Density and Compressive Strength of Concrete

Authors

  • Hari Prasetiyo Department of Civil Engineering, Faculty of Engineering, Mercu Buana University
  • Agung Sumarno Department of Civil Engineering, Faculty of Engineering, Mercu Buana University

Keywords:

Benzalkonium Chloride, Compressive Strength, Density, Disinfectant Concrete

Abstract

During the Covid-19 pandemic, where’s the number of infections was increasing every day, there were many uses of massive disinfectants as a means of suppressing the spread of viruses in the environment. No exception, buildings, structures, and residential areas are also exposed to disinfectants every day to avoid and kill the growth of invisible viruses around us. The use of chemical disinfectants such as Benzalkonium Chloride contained on floor cleaning products is often used by the public and even disinfection officers because they are easy to get. The purpose of this study was to determine the disinfectant effect of Benzalkonium Chloride with the recommended level of disinfection dissolving spray and soak (penetration) on the density and compressive strength of concrete. The method used in this research was experimental by conducting trial mixes and special treatments that are carried out at the Becakayu Toll Road Concrete Batching Plant Laboratory - PT. Waskita Beton Precast, Tbk. From the results of the study, it was concluded that the decrease in density in the concrete with Benzalkonium Chloride spray treatment and normal water spray had an average density decrease and the concrete with Benzalkonium Chloride spray had a higher reduction value than that of water spray treatment, whereas in the samples the penetration treatment of Benzalkonium Chloride and normal water curing had an average density increase and the penetration treatment of Benzalkonium Chloride had a higher density value than that of normal water curing concrete. For the results of the compressive strength of the test objects at all qualities (K-175, K-300, and K-500), Benzalkonium Chloride spray treatment and water spray experienced an increase in compressive strength at the age of 14 days but the compressive strength decreased again at the age of 28 days, whereas the benzalkonium Chloride spray treatment sample on average has a lower compressive strength than the water sprayed test sample.

Downloads

Download data is not yet available.

References

ASTM C 142-97. 1998. “Standard Test Method for Clay Lumps and Friable Particles in Aggregates.” United States: American Society for Testing and Material. 1–2.

ASTM I. n.d. “Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying (C 566).” ASTM International 5–7.

ASTM International. 2010a. “ASTM C 33. Standard Specification for Concrete Aggregates.” United States?: American Standard Testing and Material i(C):1–11.

ASTM International. 2010b. “Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens 1 This Standard Is for EDUCATIONAL USE ONLY .” Annual Book of ASTM Standards 04(C):1–7. doi: 10.1520/C0039.

Badan Standarisasi Nasional. 1990. “SNI 03:1971:1990. Metode Pengujian Kadar Air Agregat.” Jakarta: Badan Standardisasi Indonesia.

Hardianti, Hilda, S. A. Kristiawan, and Wibowo. 2017. “Pengaruh Konsentrasi Klorida Terhadap Laju Penetrasi Ion Klorida Ke Dalam Beton High Volume Fly Ash-Self Compacting Concrete ( HVFA-SCC ).” E-Jurnal Matriks Teknik Sipil.

International, ASTM. 2003. “ASTM C 29/C 29M – 97. Standard Test Method for Bulk Density (‘Unit Weight’) and Voids in Aggregate.” ASTM International 97(Reapproved):4.

Meidiani, S., and Muhammad Farsyah Septa Hartawan. 2017. “Penggunaan Variasi Ph Air (Asam) Pada Kuat Tekan Beton Normal F’C 25 MPa.” Bentang 5(2):127–34.

Pusat Penelitian dan Pengembangan Jalan dan Jembatan. 1990. “Metode Pengujian Analisis Saringan Agregat Halus Dan Kasar. SNI 03-1968-1990.” Bandung: Badan Standardisasi Indonesia 1–17.

SNI.03-4141-1996. 1996. “Metode Pengujian Gumpalan Lempung Dan Butir-Butir Mudah Pecah Dalam Agregat.” Pusjatan-Balitbang PU 1–6.

SNI 03-2816-1992. 1992. “Metode Pengujian Kotoran Organik Dalam Pasir Untuk Campuran Mortar Atau Beton.” Bandung: Badan Standardisasi Indonesia 4:2–3.

SNI 03-2834-2000. 2000. “SNI 03-2834-2000: Tata Cara Pembuatan Rencana Campuran Beton Normal.” Sni 03-2834-2000 1–34.

SNI 1970. 2008. “Standar Nasional Indonesia Cara Uji Berat Jenis Dan Penyerapan Air Agregat Halus.” Badan Standar Nasional Indonesia.

SNI 2417-2008. 2008. “Standar Nasional Indonesia Cara Uji Keausan Agregat Dengan Mesin Abrasi Los Angeles.”

SNI 2816. 2014. “Metode Uji Bahan Organik Dalam Agregat Halus Untuk Beton.” Badan Standar Nasional Indonesia 10. doi: 10.1109/CDC.2006.377159.

Statements, Bias, and Testing Size. 2003. “Standard Test Method for Materials Finer than 75- µ m ( No . 200 ) Sieve in Mineral.” American Society for Testing and Materials 04(200):3–6.

Sutandar, Erwin. 2016. “Pengaruh Pemeliharaan (Curing) Pada Kuat Tekan Beton Normal.”

The International Pharmacopoeia. 2019. “Benzalkonium Chloride ( Benzalkonii Chloridum ).” 1.

Zulnaidi. 2007. “Metodologi Penelitian.” 1–20.

Downloads

Published

2021-05-10

Issue

Section

Articles